References
Afzelius, B. A. (1979) The immotile cilia syndrome and other ciliary diseases.Int. Rev. Exp. Pathol.,19, 1–43.
Anderson, I. (1971) Mucociliary function in trachea exposed to ionized and non-ionized air. Akademisk Boghandel, Arhus. Thesis University of Arhus.
Dalhamn, T. (1955) A method for determinationin-vivo of the rate of ciliary beat and mucous flow in the trachea.Acta Physiol. Scand.,33, 1–5.
Dalhamn, T. (1960) The determinationin vivo of rate of ciliary beat in the trachea.Acta Physiol. Scand.,49, 242–250.
Dalhamn, T. andRylander, R. (1962) Frequency of ciliary beat measured with a photo-sensitive cell.Nature,196, 592–593.
Denny, F. W. (1974) Effect of a toxin produced byhaemophilus influenzae on ciliated respiratory epithelium.J. Infect. Dis.,129, 93–100.
Dulfano, M. J., Luk, C. K., Beckage, M. andWooten, O. (1981) Ciliary beat frequency in human respiratory explants.Am. Rev. Resp. Dis.,123, 139–140.
Kennedy, J. R. andRanyard, J. R. (1983) Morphology and quantitation of ciliated outgrowths from cultured rabbit tracheal explants.Europ. J. Cell Biol.,29, 200–208.
Lee, W. I. andVerdugo, P. (1977) Measurement of ciliary activity by laser light-scattering spectroscopy.Ann. Biomed. Eng.,5, 248–258.
Proetz, A. W. (1933) Studies of nasal cilia in the living mammal.Annals Oto. Rhino. Laryngol.,42, 778–788.
Rossman, C. M., Forrest, J. B., Lee, R. M. K. W. andNewhouse, M. T. (1980) The dyskenitic cilia syndrome. Ciliary motility in immotile cilia syndrome.Chest,78, 580–582.
Rutland, J., Griffin, W. M. andCole, P. J. (1982) Human ciliary beat frequency in epithelium from intrathoracic and extrathoracic airways.Am. Rev. Resp. Dis.,125, 100–105.
Sanderson, M. J. andSleigh, M. A. (1981) Ciliary activity of cultured rabbit tracheal epithelium beat pattern and metachromy.J. Cell Sci.,47, 331–347.
Smallman, L. A., Hill, S. L. andStockley, L. A. (1984) Reduction of ciliary beat frequencyin-vitro by sputum from patients with bronchiectasis: a serine proteinase effect.Thorax,39, 663–667.
van de Donk, H. J. M., Zuidema, J. andMerkes, F. W. H. M. (1980) The influence of the pH and osmotic pressure upon tracheal ciliary beat frequency with a new photo-electric registration device.Rhinol.,18, 93–104.
Verdugo, P., Johnson, N. T. andTam, P. Y. (1980) B-Adrenergic stimulation of respiratory ciliary activity.J. Appl. Physiol.: Respirat. Environ. & Exercise Physiol.,48, 868–871.
Yager, J., Chen Tzeng-Ming andDelfano, M. J. (1978) Frequency of ciliary beats of human respiratory epithelium.Chest,73, 627–633.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Teichtahl, H., Wright, P.L. & Kirsner, R.L.G. Measurement ofin vitro ciliary beat frequency: A television-video modification of the transmitted light technique. Med. Biol. Eng. Comput. 24, 193–196 (1986). https://doi.org/10.1007/BF02443935
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02443935