PAEDIATRIC LUNG DISEASE |
1 Department of Respiratory Medicine, Royal Childrens Hospital, Herston 4029, Brisbane, Australia
2 School of Medicine, Discipline of Paediatric and Child Health, University of Queensland, Herston 4029, Brisbane, Australia
3 University of Queensland, Department of Information Technology and Electrical Engineering, St Lucia 4072, Brisbane, Australia
4 University of Queensland Centre for Online Health, Royal Childrens Hospital, Herston 4029, Brisbane, Australia
5 School of Population Health, The University of Queensland, Herston 4006, Brisbane, Australia
6 Department of Thoracic Medicine, The Prince Charles Hospital, Chermside 4032, Brisbane, Australia
Correspondence to:
Correspondence to:
Dr I B Masters
Department of Respiratory Medicine, Royal Childrens Hospital, Herston 4029, Brisbane, Australia; brent_masters{at}health.qld.gov.au
Background: Accurate measurements of airway and lesion dimensions are important to the developmental progress of paediatric bronchoscopy. The malacia disorders are an important cause of respiratory morbidity in children, but no methods are currently available to measure these lesions or the airway lumen accurately. A new measurement technique is described here.
Methods: The magnification power of a paediatric videobronchoscope was defined and a simple and user friendly computer based program (Image J) was used to develop an objective technique (colour histogram mode technique, CHMT) for measurement of the airway lumen.
Results: In vivo intra-observer and inter-observer repeatability coefficients for repeated area measurements from 28 images using the Bland-Altman method were 0.9 mm2 and 1.6 mm2, respectively. The average intraclass correlation coefficient for repeated measurements of area was 0.93. In vitro validation measurements using a 2 mm diameter tube resolved radii measurements to within 0.1 mm (coefficient of variability 8%). An "acceptable result" was defined in 92% of 734 images completed with the CHMT alone and 8% with its modification. The success rate for two of three images being within 10% of each others area was 100%. Measurements of cricoid cross sectional areas from 116 patients compared with expected airway areas for age derived from endotracheal tube sizes were comparable.
Conclusions: The CHMT method of identifying and measuring airway dimensions is objective, accurate, and versatile and, as such, is important to the future development of flexible videobronchoscopy.
Abbreviations: CHMT, colour histogram mode technique; FVB, flexible videobronchoscopy
Keywords: flexible videobronchoscopy; children; airway measurement
This article has been cited by other articles:
![]() |
N. Jowett, R. A. Weersink, K. Zhang, P. Campisi, and V. Forte Airway Luminal Diameter and Shape Measurement by Means of an Intraluminal Fiberoptic Probe: A Bench Model Arch Otolaryngol Head Neck Surg, June 1, 2008; 134(6): 637 - 642. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. B. Masters, P. V. Zimmerman, N. Pandeya, H. L. Petsky, S. B. Wilson, and A. B. Chang Quantified Tracheobronchomalacia Disorders and Their Clinical Profiles in Children Chest, February 1, 2008; 133(2): 461 - 467. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS | REGISTER |