Thorax

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

Published Online First: 5 August 2005. doi:10.1136/thx.2005.041327
Thorax 2005;60:859-864
Copyright © 2005 BMJ Publishing Group Ltd & British Thoracic Society

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Web-only appendix
Right arrow Web-only appendix
Right arrow All Versions of this Article:
thx.2005.041327v1
60/10/859    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tuggey, J M
Right arrow Articles by Elliott, M W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tuggey, J M
Right arrow Articles by Elliott, M W

ASSISTED VENTILATION

Randomised crossover study of pressure and volume non-invasive ventilation in chest wall deformity

J M Tuggey, M W Elliott

Department of Respiratory Medicine, St James’s University Hospital, Leeds LS9 7TF, UK

Correspondence to:
Correspondence to:
Dr J M Tuggey
Department of Respiratory Medicine, Airedale General Hospital, Keighley, West Yorkshire BD20 6TD, UK; justin.tuggey{at}antist.nhs.uk

Background: Non-invasive ventilation is an established treatment for chronic respiratory failure due to chest wall deformity. There are few data available to inform the choice between volume and pressure ventilators. The aim of this study was to compare pressure and volume targeted ventilation in terms of diurnal arterial blood gas tensions, lung volumes, hypercapnic ventilatory responses, sleep quality, and effect on daytime function and health status when ventilators were carefully set to provide the same minute ventilation.

Methods: Thirteen patients with chest wall deformity underwent a 4 week single blind randomised crossover study using the Breas PV403 ventilator in either pressure or volume mode with assessments made at the end of each 4 week period.

Results: Minute ventilation at night was less than that set during the day with greater leakage for both modes of ventilation. There was more leakage with pressure than volume ventilation (13.8 (1.9) v 5.9 (1.0) l/min, p = 0.01). There were no significant differences in sleep quality, daytime arterial blood gas tensions, lung mechanics, ventilatory drive, health status or daytime functioning.

Conclusions: These data suggest that pressure and volume ventilation are equivalent in terms of the effect on nocturnal and daytime physiology, and resulting daytime function and health status.


Keywords: positive pressure ventilation; hypercapnic responses; health related quality of life; chronic respiratory failure; chest wall deformity; non-invasive ventilation




This article has been cited by other articles:


Home page
ChestHome page
B. Mokhlesi and A. Tulaimat
Recent Advances in Obesity Hypoventilation Syndrome
Chest, October 1, 2007; 132(4): 1322 - 1336.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. H. Storre, B. Seuthe, R. Fiechter, S. Milioglou, M. Dreher, S. Sorichter, and W. Windisch
Average volume-assured pressure support in obesity hypoventilation: a randomized crossover trial.
Chest, September 1, 2006; 130(3): 815 - 821.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2005 BMJ Publishing Group Ltd & British Thoracic Society