Thorax

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chan, E Y
Right arrow Articles by McKenzie, S A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chan, E Y
Right arrow Articles by McKenzie, S A
Thorax 2003;58:344-347
© 2003 BMJ Publishing Group & British Thoracic Society


RESPIRATORY PHYSIOLOGY

Repeatability of airway resistance measurements made using the interrupter technique

E Y Chan1, P D Bridge1, I Dundas1, C S Pao1, M J R Healy2, S A McKenzie1

1 Department of Respiratory Paediatrics, Fielden House, The Royal London Hospital, Barts and The London NHS Trust, London E1 1BB, UK
2 Department of Mathematics, Institute of Education, London WC1H 0AL, UK

Correspondence to:
Correspondence to:
Dr S A McKenzie, Department of Respiratory Paediatrics, Fielden House, The Royal London Hospital, London E1 1BB, UK;
S.A.McKenzie{at}qmul.ac.uk


ABSTRACT
Background: To be able to interpret any measurement, its repeatability should be known. This study reports the repeatability of airway resistance measurements using the interrupter technique (Rint) in children with and without respiratory symptoms.

Methods: Children aged 2–10 years who were healthy, had persistent isolated cough, or who had previous wheeze were studied. On the same occasion, three Rint measurements were made 15 minutes apart, before and after placebo and salbutamol given in random order. Results from those given placebo first were analysed for within-occasion repeatability. Between-occasion repeatability measurements were made 2–20 weeks apart (median 3 weeks).

Results: For 85 pairs of measurements before and after placebo the limits of agreement were 20% expected resistance and were unaffected by age or health status. The change in resistance following bronchodilator in one of 18 healthy children, 12 of 28 with cough, and 22 of 39 with wheeze exceeded this threshold. For between-occasion measurements the limits of agreement were 32% in 72 healthy subjects, 49% in 57 with cough, and 53% in 95 with previous wheeze.

Conclusion: The measurement of airways resistance by the interrupter technique is clinically meaningful when change following an intervention such as the administration of bronchodilator is greater than its within-occasion repeatability. Between-occasion repeatability is too poor to judge change confidently.


Keywords: lung function test; interrupter technique; repeatability




This article has been cited by other articles:


Home page
Proc Am Thorac SocHome page
S. D. Davis, A. S. Brody, M. J. Emond, L. C. Brumback, and M. Rosenfeld
Endpoints for Clinical Trials in Young Children with Cystic Fibrosis
Proceedings of the ATS, August 1, 2007; 4(4): 418 - 430.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
EDUCATION AND PRACTICEHome page
A. Gupta, M. McKean, and A. B Chang
Management of chronic non-specific cough in childhood: an evidence-based review
Arch. Dis. Child. Ed. Pract., April 1, 2007; 92(2): 33 - 39.
[Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
M R Thomas, G F Rafferty, R Blowes, J L Peacock, N Marlow, S Calvert, A Milner, and A Greenough
Plethysmograph and interrupter resistance measurements in prematurely born young children
Arch. Dis. Child. Fetal Neonatal Ed., May 1, 2006; 91(3): F193 - F196.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J.J. Pillow, H. Ljungberg, G. Hulskamp, and J. Stocks
Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer
Eur. Respir. J., May 1, 2004; 23(5): 763 - 768.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
I Dundas, S A McKenzie, E Lombardi, and P D Sly
Interrupter resistance
Thorax, May 1, 2004; 59(5): 449 - 450.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. E. Brussee, H. A. Smit, L. P. Koopman, A. H. Wijga, M. Kerkhof, K. Corver, A. P. H. Vos, J. Gerritsen, D. E. Grobbee, B. Brunekreef, et al.
Interrupter Resistance and Wheezing Phenotypes at 4 Years of Age
Am. J. Respir. Crit. Care Med., January 15, 2004; 169(2): 209 - 213.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
P D Sly and E Lombardi
Measurement of lung function in preschool children using the interrupter technique
Thorax, September 1, 2003; 58(9): 742 - 744.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2003 BMJ Publishing Group Ltd & British Thoracic Society