Thorax

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harrison, T W
Right arrow Articles by Tattersfield, A E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harrison, T W
Right arrow Articles by Tattersfield, A E
Thorax 2003;58:258-260
© 2003 BMJ Publishing Group & British Thoracic Society


SHORT PAPER

Plasma concentrations of fluticasone propionate and budesonide following inhalation from dry powder inhalers by healthy and asthmatic subjects

T W Harrison, A E Tattersfield

T W Harrison, A E Tattersfield, Respiratory Medicine, Nottingham City Hospital, Nottingham NG5 1PB, UK

Correspondence to:
Correspondence to:
Dr T W Harrison, Respiratory Medicine, Nottingham City Hospital, Nottingham NG5 1PB, UK;
tharris2{at}ncht.org.uk


ABSTRACT
Background: All currently available inhaled corticosteroids reach the systemic circulation and have the potential to produce adverse effects with long term use. This risk is often assessed by measuring the effect of different inhaled corticosteroids on the hypothalamic-pituitary-adrenal (HPA) axis in healthy subjects. Absorption of fluticasone propionate and its effects on the HPA axis are greater in healthy subjects than in subjects with moderately severe asthma, but we have failed to show any difference in morning budesonide plasma levels or systemic effects between healthy and asthmatic subjects following inhalation of budesonide. To provide more information on the absorption of fluticasone propionate and budesonide, we have compared the plasma levels of both drugs over 8 hours in healthy and asthmatic subjects.

Methods: The area under the plasma concentration-time curves (AUC) and the maximum concentration (Cmax) of fluticasone propionate and budesonide after a single inhaled dose of each drug were compared in 12 healthy control subjects and 12 subjects with moderately severe asthma.

Results: Peak plasma levels of budesonide occurred much earlier and were approximately 20-fold higher than those of fluticasone propionate in both healthy and asthmatic subjects. The AUC and Cmax for fluticasone propionate were lower by 307 (95% CI 62 to 522) pg/ml/h or 43% (p=0.02) and 52 (95% CI –11 to 115) pg/ml or 39% (p=0.1) in subjects with asthma compared with healthy control subjects. In contrast, the AUC and Cmax for budesonide were almost identical between the two groups (mean differences 826 (95% CI –1493 to 3143) pg/ml/h (p=0.5) and 157 (95% CI –1026 to 1339) pg/ml (p=0.8).

Conclusions: Following inhalation, healthy subjects have higher plasma levels of fluticasone propionate than subjects with asthma whereas budesonide plasma levels are similar in the two groups of subjects. Comparing the systemic effects of budesonide and fluticasone propionate in healthy subjects is unlikely to be relevant to subjects with asthma.


Keywords: inhaled corticosteroids; fluticasone propionate; budesonide; plasma levels; asthma




This article has been cited by other articles:


Home page
Therapeutic Advances in Respiratory DiseaseHome page
B. Lindmark
Review: Differences in the pharmacodynamics of budesonide/formoterol and salmeterol/fluticasone reflect differences in their therapeutic usefulness in asthma
Therapeutic Advances in Respiratory Disease, October 1, 2008; 2(5): 279 - 299.
[Abstract] [PDF]


Home page
Eur Respir JHome page
M. Masoli, M. Weatherall, S. Holt, P. Shirtcliffe, and R. Beasley
Inhaled fluticasone propionate and adrenal effects in adult asthma: systematic review and meta-analysis
Eur. Respir. J., November 1, 2006; 28(5): 960 - 967.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
K J Mortimer, L J Tata, C J P Smith, J West, T W Harrison, A E Tattersfield, and R B Hubbard
Oral and inhaled corticosteroids and adrenal insufficiency: a case-control study
Thorax, May 1, 2006; 61(5): 405 - 408.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. K. C. Lee, T. C. Fardon, C. E. Bates, K. Haggart, L. C. McFarlane, and B. J. Lipworth
Airway and Systemic Effects of Hydrofluoroalkane Formulations of High-Dose Ciclesonide and Fluticasone in Moderate Persistent Asthma
Chest, March 1, 2005; 127(3): 851 - 860.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
K. Biggadike, I. Uings, and S. N. Farrow
Designing Corticosteroid Drugs for Pulmonary Selectivity
Proceedings of the ATS, December 1, 2004; 1(4): 352 - 355.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
A. E. Tattersfield, T. W. Harrison, R. B. Hubbard, and K. Mortimer
Safety of Inhaled Corticosteroids
Proceedings of the ATS, November 1, 2004; 1(3): 171 - 175.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
T. W. Harrison, A. E. Tattersfield, R. J. Martin, and S. J. Szefler
Systemic effects of inhaled corticosteroids
Am. J. Respir. Crit. Care Med., April 1, 2003; 167(7): 1037 - 1038.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2003 BMJ Publishing Group Ltd & British Thoracic Society